The Center-Vent Slider Windows are three-track external screen thermal-break sliding windows with a 93 mm system wall occupation, suitable for Southeast Asia, Australia, coastal residences, villa kitchens, bedrooms, balconies, dormitories, and rental apartments.
- External screen sash slides independently with a maximum recommended width of about 1300 mm and uses 304 stainless steel safety mesh for mosquito, corrosion, and impact resistance.
- One-piece outer frame reduces splicing seams.
- DERCHI provides one-stop service from product consultation, scheme design, order production to delivery, with products having passed NFRC, AS2047, CE, CSA, and ISO9001 certifications.
Product Details
WT-93 is a three-track external screen thermal-break sliding window under the E2T new system, using a 6063-T5 thermal-break aluminum profile with PA66 thermal break strips and a continuous thermal break at frame, sash and track. Three independent tracks carry glass sashes and an external protective screen sash separately, so the screen sash does not occupy the glass sliding channel; the three-track structure places the screen sash on the outdoor side, keeping the indoor side for glass sash and handle operation. Glass sashes run on customized silent pulleys with stainless steel load-bearing components, and the track cooperates with upper anti-swing and anti-theft limit blocks to control sash jumping and lifting. The one-piece outer frame reduces splicing seams, and the track uses height difference and chambered drainage.
WT-93 is available in three-sash three-track or six-sash three-track combinations, with extended configurations including left-right fixed center opening, top light, bottom fixed and large-area combination windows. Adjustable items include fixed glass ratio, mullion position, glass type, mesh density, locks, drainage cover color and edge wrapping. For developers, the WT-93 value is integrating the screen into the system track rather than post-installed external hanging; for dealers, the 93 mm system depth, 1.8 mm profile and three-track safety mesh form a clearer upgrade gradient than ordinary two-track light windows. Product data can list finished width/height, three or six sash, opening direction, fixed area, glass construction, mesh type, color, handle and lock, edge wrapping and installation method by window number.
Product Features
WT-93 is a three-track external screen thermal-break sliding window under the E2T new system, corresponding to the Center-Vent Slider Windows title — identifies the system tier for specification matching.
Three independent tracks carry glass sashes and external screen sash separately; the screen sash does not occupy the glass sliding channel, so screen protection does not reduce glass openable area compared to two-track windows.
System wall occupation is 93 mm with indoor and outdoor main visible face about 43 mm — wall cavity and reveal dimensions are confirmed before ordering.
Profile is 6063-T5 thermal-break aluminum with outer frame and opening sash main wall thickness of 1.8 mm — profile grade and wall thickness are matched to structural and wind-load requirements.
PA66 thermal break strips measure about 24 mm (outer frame), 32 mm (fixed frame) and 15 mm (sash), forming a continuous thermal break at frame, sash and track — thermal-break continuity is confirmed for insulation-sensitive projects.
External screen uses 304 stainless steel safety mesh for mosquito resistance, corrosion resistance and impact resistance — mesh grade is selected for coastal or pet-occupied sites.
External screen sash slides independently with maximum recommended width about 1300 mm and is removable for cleaning — screen panel width is sized within the recommended limit.
Screen mesh bending adds only about 18 mm width with no height increase — reveal width is planned without additional vertical clearance.
Track cooperates with upper anti-swing and anti-theft limit blocks; hardware includes Moor bar lock, upper anti-theft block, universal transmission and limit accessories — security hardware level is specified for low-rise or ground-floor units.
Track uses height difference and chambered drainage; first drainage position is about 200 mm from side frame with staggered inner and outer holes and zinc alloy drainage covers — drainage configuration is selected for rain-exposed elevations.
Sliding overlap area uses siliconized weatherstrip — seal type is specified for air-tightness requirements.
Adjustable items include fixed glass ratio, mullion position, glass type, mesh density, locks, drainage cover color and edge wrapping, defined per window number in project data — configuration variables are set per opening.
Simulated performance grades: thermal insulation 5, sound insulation 3, water tightness 4, air tightness 6, wind pressure resistance 9 — grades are compared against project performance thresholds.
Customizable Styles
Standard glass: 5 mm + 12A + 5 mm double tempered insulating glass with PVVB spacer; optional glass types include Low-E, tinted, coated, laminated, frosted, or motorized louver glass.
Engineering colors: Quartz Gray, Deep Coffee, Caramel Coffee, Black Crystal, Star Black, Skin Black, and Pearl White.
Extended finishes: wood grain, fluorocarbon, powder coating, and indoor-outdoor dual color.
Fixed glass sealing option: neutral silicone sealant or Haida rubber strip.
Single glass active sash range: width 350–1100 mm, height 500–1600 mm.
Single fixed glass maximum area: about 6 m².
Screen sash maximum recommended width: about 1300 mm.
Hardware Accessories
Standard hardware includes Moor bar lock, upper anti-theft block, and universal transmission and limit accessories.
Upper anti-swing limit blocks and anti-theft limit blocks cooperate with the track to control sash jumping and lifting.
Customized silent pulleys and stainless steel load-bearing components are used in the sliding system.
Zinc alloy drainage covers are fitted to the track's height-difference and chambered drainage design.
Optional key locks and limiters can be added for low-rise residences, balconies, and pet families.
Three-track structure places screen sash on the outdoor side, keeping the indoor side for glass sash and handle operation.
Basic Parameters
Performance Dimension | Grade (Simulated) | What It Means | Test Method | Evidence to Request |
|---|---|---|---|---|
Thermal Insulation | 5 | Resistance to heat transfer through the window assembly, relevant for energy performance in heated or cooled spaces. | Thermal transmittance (U-value) measurement of the complete window assembly. | Thermal transmittance test report for the 6063-T5 thermal-break aluminum profile with PA66 strips. |
Wind Pressure Resistance | 9 | Capacity of the window assembly to withstand wind loads without structural failure or excessive deflection. | Wind load testing of the installed window assembly under pressure differentials. | Wind load test report covering the staggered drainage configuration and zinc alloy drainage covers. |
Water Tightness | 4 | Resistance to water penetration under wind-driven rain, relevant for weathertightness in exposed installations. | Water penetration resistance testing under simultaneous spray and pressure differential. | Water penetration resistance test report confirming the staggered inner and outer drainage hole performance. |
Air Tightness | 6 | Resistance to air leakage through gaps in the sash and frame, relevant for draft control and energy performance. | Air leakage rate measurement of the complete sash assembly under pressure differential. | Air leakage test report for the complete sash assembly. |
Sound Insulation | 3 | Reduction of airborne sound transmission through the window, relevant for acoustic comfort near noise sources. | Sound transmission loss measurement of the glazed window assembly. | Sound transmission class test report for the specified glazing configuration. |
Product Specifications
Specification | Value |
|---|---|
System wall occupation | 93 mm |
Indoor / outdoor main visible face | about 43 mm |
Indoor mullion visible face | about 8 mm |
Outdoor mullion visible face | about 60 mm |
Glass sash thickness | about 34 mm |
Glass sash visible face | about 58 mm |
Screen sash thickness | about 23.6 mm |
Screen sash visible face | about 58 mm |
Profile wall thickness | 1.8 mm |
Standard glass | 5 mm + 12A + 5 mm double tempered insulating glass |
PA66 thermal break strip — outer frame | about 24 mm |
PA66 thermal break strip — fixed frame | about 32 mm |
PA66 thermal break strip — sash | about 15 mm |
Single glass active sash width range | 350–1100 mm |
Single glass active sash height range | 500–1600 mm |
Single fixed glass maximum area | about 6 m² |
Screen mesh bending width addition | about 18 mm |
First drainage position from side frame | about 200 mm |
Opening type and slider direction
Frame opening dimensions (width × height)
Active sash dimensions (width × height)
Fixed glass dimensions (width × height)
Glass configuration
Profile color and finish
Screen mesh type and material
Installation location and wall condition
Required quantity and delivery schedule
Advantages
DERCHI operates an about 150,000 m² modern production base with a 4.0 intelligent automated production line and annual capacity of about 600,000-800,000 m².
DERCHI maintains a national standard testing center and applies 100% full inspection before shipment; products have passed NFRC, AS2047, CE, CSA, and ISO9001 certifications.
Product data can list finished dimensions, sash count, opening direction, fixed area, glass construction, mesh type, color, hardware, edge wrapping, and installation method by window number.
Packaging is designed for on-site installation by window number with layered fixing of glass and screen sashes, suitable for large-volume, stable project delivery.
DERCHI's one-stop service spans product consultation, scheme design, order production, and delivery; a team of 20+ professional R&D experts has accumulated 100+ national patents covering invention, appearance, and design patents.
Over 15 years of industry experience with 200,000+ completed cases, 600+ employees, 700+ dealers, and business covering 100+ countries.
Application Scenarios
Project condition | Evidenced fit | Conditions to check before specifying |
|---|---|---|
Southeast Asia and Australia residences | Documented as suitable for Southeast Asia and Australia projects. | Confirm local wind-load and corrosion-exposure requirements for the specific site. |
Tropical, coastal, mosquito-prone areas | Listed as an applicable environment for the product. | Verify that the external screen configuration meets the site's insect and mosquito pressure. |
Coastal residences | Identified as a suitable application. | Check salt-air exposure class and compatible frame finish availability. |
Villa kitchens, bedrooms, and balconies | Named as fitting room-level applications. | Confirm opening size and sill height suit each room type. |
Dormitories and rental apartments | Recorded as suitable use cases. | Validate ventilation volume and screen access match occupancy patterns. |
Residences and apartments needing daily large ventilation | Stated as an applicable scenario. | Confirm three-track sliding travel meets the required airflow opening. |
Low-rise residences and pet families | Listed as applicable project conditions. | Verify screen strength and latch security for pet interaction. |
Commercial buildings and high-end engineering | Projects cover residences, villas, commercial buildings and high-end engineering. | Confirm brand-level specification and documentation requirements with the project team. |
FAQ
What must be confirmed technically?
The screen is integrated into the system track rather than post-installed as an external hanging. The system has a 93 mm depth with a 1.8 mm profile and a three-track safety mesh.
What should buyers prepare for volume procurement?
Packaging is designed for on-site installation by window number with layered fixing of glass and screen sashes. The product is suitable for large-volume, stable project delivery. A one-stop service covers product consultation, scheme design, order production, and delivery.
Which test reports or compliance documents must be confirmed for the project?
Request test reports covering structural, weather-tightness, thermal, and acoustic categories, along with any compliance documentation required by local building codes, before placing an order.
Which product details require confirmation before selection?
Confirm opening dimensions, sash configuration, glass type, mesh type, color, and installation method for each window opening before finalizing the selection.
Which commercial terms and documents must be confirmed before quotation?
Clarify Incoterms, payment milestones, delivery schedule, warranty scope, and after-sales responsibilities with the supplier before requesting a quotation.
Which hardware options require project-specific confirmation?
Confirm lock type, handle style, and mesh engagement mechanism against project-specific security and ventilation requirements.